Showing posts with label ENTOMED Made in Sweden. Show all posts
Showing posts with label ENTOMED Made in Sweden. Show all posts

Sunday, August 16, 2015

Audiometer merek ENTOMED tipe SA 204 Made in Sweden



SA 204 is a manual / automatic, true two-channel, diagnostic audiometer with full frequency and output range for pure-tone air, bone conduction, speech and synchronized masking. Its patented digital design and RoHS compatibility makes it well adapted to the modern, environmentally aware user. SA 204 is user friendly, robust, reliable and yet, its light-weight design makes it ideal for frequent field use. Built-in talk forward microphone for convenient communication. SA 204 stores up to 50 audiograms, with date and subject identification, allowing for hard copy prints and/or transfer to a computer at any time. Calibrates to a range of selected audiometric air conduction earphones and bone conduction vibrator. Free-field system is optional. SA 204 is NOAH-compatible when using Entomed Audi-Link 1.00 for NOAH 3. SA 204 is ideal for hearing threshold and diagnostic determination, designed for frequent clinical practise and portable field use.
Function
SA 204 is a manual/automatic pure-tone, bone conduction and speech testing diagnostic audiometer with narrow band and speech noise masking possibilities. The SA 204 has a set-up menu, which allows the audiometer to be programmed according to individual needs. 50 audiograms with date, time and personal identification can be stored in the internal memory. Each audiogram can be displayed, transferred to a computer and/or external printer at any time. SA 204 is as standard equipped with a monitor headset and a talkback microphone for optimal communication with the test subject. Live Speech Monitor Headset and Free Field systems are optional. SA 204 calibrates to TDH-39/DD45/HDA200 earphones, ER-5A insert earphones and Radioear B71 bone vibrator.
Signal format
Single pulse (1.3 sec duration)
Continuous pure-tone when button is maintained active
Pulsing (2.5 pulse/sec)
Frequency modulation (± 5 %)
Special Capabilities
Built-in talk forward microphone with volume control.
Internal memory - stores up to 50 complete audiograms in nonvolatile memory
Synchronized Masking - The level of masking will automatically track with the stimulus level
Hard copy print-outs to any PCL 5 printer, via optional SA 07 printer interface cable
Computer interface, via optional RS 232 computer cable
Transfer possibilities to NOAH 3 when using optional Entomed Audi-Link 1.00 for NOAH 3
Dimensions
Width* Height* Depth: 376* 73* 264 (mm)
Weight: 1,5 kg
Power supply: 110 V - 240 V, 50 - 60 Hz


Monday, August 3, 2015

Audiometer merek ENTOMED tipe SA 203 Made in Sweden





SA 203 is a manual / automatic, true two-channel, diagnostic audiometer with full frequency and output range for pure-tone air, bone conduction and synchronized masking possibilities. Its patented digital design and RoHS compatibility makes it well adapted to the modern, environmentally aware user. SA 203 is user friendly, robust, reliable and yet its light-weight design makes it ideal for frequent field use. Built-in talk forward microphone for convenient communication. SA 203 stores up to 50 audiograms, with date and subject identification, allowing for hard copy prints and/or transfer to a computer at any time. Calibrates to a range of selected audiometric air conduction earphones and bone conduction vibrator. Free-field system is optional. SA 203 is NOAH-compatible when using Entomed Audi-Link 1.00 for NOAH 3. SA 203 is ideal for hearing threshold and diagnostic determination, designed for frequent practise and portable field use.
Function
SA 203 is a manual/automatic pure-tone and bone conduction diagnostic audiometer with narrow band masking possibilities. The SA 203 has a set-up menu, which allows the audiometer to be programmed according to individual needs.
50 audiograms together with date, time and personal identification can be stored in the internal memory. Each audiogram can be displayed, transferred to a computer and/or external printer at any time. Built-in microphone for convenient communication with the test subject. Free field speaker system is optional. SA 203 calibrates to TDH39/DD45/HDA200 earphones, ER-5A insert earphones and Radioear B71 bone vibrator.
Signal format
Single pulse (1.3 sec duration)
Continuous pure-tone when button is maintained active
Pulsing (2.5 pulse/sec)
Frequency modulation (± 5 %)
Special Capabilities
Built-in talk forward microphone with volume control
Internal memory - stores up to 50 complete audiograms in nonvolatile memory
Synchronized Masking - The level of masking will automatically track with the stimulus level
Hard copy print-outs to any PCL 5 printer, via optional SA 07 printer interface cable
Computer interface, via optional RS 232 computer cable RS 232 interface
Transfer possibilities to NOAH 3 when using Entomed Audi-Link 1.00 for NOAH 3
Dimensions
Width* Height* Depth: 376* 73* 264 (mm)
Weight: 1.5 kg
Power supply: 110 V - 240 V, 50 - 60 Hz




Audiometer merek ENTOMED tipe SA 201 Made in Sweden



SA 201 is a basic manual, true two-channel, pure-tone, air conduction screening audiometer with full frequency and output range. Its patented digital design and RoHS compatibility makes it well adapted to the modern, environmentally aware user. SA 201 is user friendly, robust, reliable and yet its light-weight design makes it ideal for frequent field use. Built-in talk forward microphone for convenient communication. SA 201 allows storage of the last audiogram for after-test evaluation. Calibrates to a range of selected audiometric air conduction earphones. SA 201 is ideal for screening and hearing threshold determination, designed for frequent practise and portable field use.


Function
SA 201 is a basic manual pure-tone screening audiometer. It has a set-up menu, which allows the audiometer to be programmed according to individual needs. The test results can be viewed on the display by scrolling through the frequency range. For each frequency the corresponding threshold level is shown on the display. Built-in talk forward microphone for convenient communication with the test subject. SA 201 calibrates to TDH39/DD45/HDA200 earphones and ER-5A insert earphones.


Signal Format
Single pure-tone pulse (1.3 sec duration)
Continuous pure-tone, when maintaining button active
Pulsing (2.5 pulse/sec)
Frequency modulation (± 5 %)


Special Capabilities
Built-in talk forward microphone with volume control
Storage of last audiogram for after-test evaluation


Dimensions
Width* Height* Depth: 376* 73* 264 (mm)
Weight: 1.5 kg
Power supply: 110 V - 240 V, 50 - 60 Hz


Audiometer merek ENTOMED tipe SA 202 Made in Sweden



SA 202 is a manual / automatic, true two-channel, pure-tone, air conduction screening audiometer with full frequency and output range. Its patented digital design and RoHS compatibility makes it well adapted to the modern, environmentally aware user. SA 202 is user friendly, robust, reliable and yet its light-weight design makes it ideal for frequent field use. Built-in talk forward microphone for convenient communication. SA 202 stores up to 50 audiograms, with date and subject identification, allowing for hard copy prints and/or transfer to a computer at any time. Calibrates to a range of selected audiometric air conduction earphones. SA 202 is ideal for screening and hearing threshold determination, designed for frequent practise and portable field use.
Function
SA 202 is a manual/automatic pure-tone screening audiometer. It has a set-up menu, which allows the audiometer to be programmed according to individual needs. 50 audiograms with date, time and personal identification can be stored in the internal memory. Each audiogram can be displayed, transferred to a computer and/or external printer at any time. Built-in talk forward microphone for convenient communication with the test subject. SA 202 calibrates to TDH39/DD45/HDA200 earphones and ER-5A insert earphones.
Signal Format
Single pulse (1.3 sec duration)
Continuous pure-tone when button is maintained active
Pulsing (2.5 pulse/sec)
Frequency modulation (± 5 %)
Special Capabilities
Built-in talk forward microphone with volume control
Internal memory - stores up to 50 complete audiograms in nonvolatile memory
Hard copy print-outs to any PCL 5 printer, via optional SA 07 printer interface cable
Computer interface, via optional RS 232 computer cable
Dimensions
Width* Height* Depth: 376* 73* 264 (mm)
Weight: 1.5 kg
Power supply: 110 V - 240 V, 50 - 60 Hz